1.Design Features
FLD-903P digital step voltage pinpointing device
l Indicate the fault point direction directly, find the fault point easily
l High sensitivity and widely responding range
l Digital signal processing technology to display signal waveform directly. High anti-interference
l Automatic zero setting to offset ground potential variation effect
l Testing the resistive current by current transducer and cable fault section
l High capacity rechargeable lithium battery.Max.15 hours work time
l Low battery indication.
l Auto power off when under-voltage and long-time no-operation
2.Tech. Specifications
Signal receiving mode | Voltage signal: probe input Current signal: current transducer input |
Max. testing sensitivity | Voltage signal 0.1mV;Current signal 5mA |
Signal max. input range | Probe 300V |
Display | Signal waveform, fault point direction, battery lever |
Power supply | 7.4V,2400Mah rechargeable |
Volume | 210mm×122mm×125mm;probe: Φ30×1100mm |
Weight | Main unit:0.5kgs;probe:0.5kgs |
Operating Temperature | -10℃-40℃ |
Humidity | 5-90%RH |
Elevation | <4500m |